Error Code tC5
A secondary temperature sensor is giving bad readings
Moderate
Address soon - your appliance may not work properly
Also displayed as: tC5
What This Means
Thermistor 2 resistance out of range (open or shorted); Damaged thermistor 2 wiring; Restricted vent system causing temperature abnormality
What actually causes this:
Similar to the main temperature sensor error — usually caused by lint buildup restricting airflow, or the sensor itself has worn out.
First Thing to Check
Clean the lint screen thoroughly and make sure the exhaust vent path is clear.
Parts Involved
How to Fix
- 1
1. Check and clean the lint screen
- 2
2. Inspect the exhaust vent system for restrictions
- 3
3. Measure thermistor 2 resistance at room temperature
- 4
4. If resistance is out of range, replace thermistor 2
This Error Applies To
Samsung DVE41A3000 Series Dryers (2020) (2020–present)