Samsung Dryers2024–present

Error Code FC

Your dryer is getting the wrong type of electrical power

Moderate

Address soon - your appliance may not work properly

Also displayed as: FC

What This Means

Not using regular power source frequency (not 60Hz); Invalid power frequency sensor circuit on PCB; Generator or inverter power supply with unstable frequency

What actually causes this:

The power supply frequency is outside the expected range — usually a generator or unstable power issue.

First Thing to Check

If you're running the dryer on a generator, try plugging it into a regular wall outlet instead.

Parts Involved

Main PCB (Main PBA)Power Supply

How to Fix

  1. 1

    1. Check if you are using regular power source frequencies (60Hz)

  2. 2

    2. Check if dryer is connected to a generator or inverter -- these may not provide stable 60Hz

  3. 3

    3. Check the power frequency sensor circuit on main PCB

  4. 4

    4. Test with known good 60Hz power source

This Error Applies To

Samsung DVE55A7300 Series Dryers (2024) (2024–present)

Service manual exact match: DVE55A7700V/A3Service manual exact match: DVG55A7300E/A3Service manual exact match: DVG52A5500V/A3Service manual exact match: DVE55A7300V/A3Service manual exact match: DVE52A5500W/A3Service manual exact match: DVG52A5500C/A3Service manual exact match: DVE55A7300E/A3Service manual exact match: DVE52A5500V/A3+2 more