Samsung Dryers2024–present

Error Code tC

Your dryer's temperature sensor isn't reading correctly

Moderate

Address soon - your appliance may not work properly

Also displayed as: tC

What This Means

Clogged lint screen restricting airflow and causing abnormal temperature readings; Restricted vent system causing heat buildup; Thermistor resistance out of range (open or shorted)

What actually causes this:

Usually a clogged lint screen or blocked exhaust vent — restricted airflow causes the sensor to misread temperatures.

First Thing to Check

Pull out the lint screen and clean off all the lint, then check that your exhaust vent hose isn't kinked or blocked.

Parts Involved

Thermistor 1Lint ScreenVent System

How to Fix

  1. 1

    1. Check and clean the lint screen

  2. 2

    2. Check if the vent system is restricted

  3. 3

    3. Measure thermistor resistance: should be 10KOhm at 25 degrees C (77 degrees F) for electric models, or 238.23KOhm at 25 degrees C for gas models

  4. 4

    4. If thermistor resistance is out of range, replace the thermistor

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

This Error Applies To

Samsung DVE55A7300 Series Dryers (2024) (2024–present)

Service manual exact match: DVE55A7700V/A3Service manual exact match: DVG55A7300E/A3Service manual exact match: DVG52A5500V/A3Service manual exact match: DVE55A7300V/A3Service manual exact match: DVE52A5500W/A3Service manual exact match: DVG52A5500C/A3Service manual exact match: DVE55A7300E/A3Service manual exact match: DVE52A5500V/A3+2 more

Need more help with your Samsung dryers?