Error Code tC5
A secondary temperature sensor is giving bad readings
Moderate
Address soon - your appliance may not work properly
Also displayed as: tC5 (Upper and Lower)
What This Means
Clogged lint screen restricting airflow and causing abnormal temperature readings; Restricted vent system causing heat buildup; Thermistor 2 resistance out of range (open or shorted)
What actually causes this:
Similar to the main temperature sensor error — usually caused by lint buildup restricting airflow, or the sensor itself has worn out.
First Thing to Check
Clean the lint screen thoroughly and make sure the exhaust vent path is clear.
Parts Involved
How to Fix
- 1
1. Check for a clogged lint screen
- 2
2. Check if the vent system is restricted
- 3
3. Measure thermistor resistance
- 4
4. If thermistor resistance is out of range, replace the thermistor
Parts Commonly Needed for This Error
OEM part numbers confirmed by retailers
This Error Applies To
Samsung DVE60A9900 Series Dryers
Related Error Codes
Your dryer is getting the wrong voltage from the outlet
Your dryer is getting the wrong type of electrical power
Your dryer's temperature sensor isn't reading correctly
The dryer's internal parts aren't communicating properly
The dryer thinks the door is open while running
Your dryer isn't heating properly or is overheating
The door switch isn't working properly