Samsung Ovens & Ranges2020–present

Error Code C-30

PCB internal temperature sensor open circuit

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: C-30

What This Means

Broken NTC sensor on PCB; Poor solder connection; Open circuit in sensor trace

What actually causes this:

The PCB temperature sensor is broken internally or has a bad solder joint

First Thing to Check

Visually inspect the small NTC sensor component on the main PCB for obvious damage

Parts Involved

Main PCBNTC200 sensor component

How to Fix

  1. 1

    Disconnect electrical power

  2. 2

    Remove back cover

  3. 3

    Remove PCB and visually inspect NTC sensor

  4. 4

    Measure NTC sensor resistance (should be 3200 ohms at room temperature)

This Error Applies To

Samsung DOB30P977D Series Ovens & Ranges (2020) (2020–present)

Service manual exact match: DOB30P977DSService manual exact match: NV51M9770DS

Need more help with your Samsung ovens & ranges?