Error Code C-F0
Main and sub control board communication failure
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: C-F0
What This Means
Disconnected wire harness; Loose connector; Outdated software version
What actually causes this:
The cable between the main and sub control boards is loose or disconnected
First Thing to Check
Visually inspect the ribbon cable between Main PCB and Sub PCB
Parts Involved
How to Fix
- 1
Check wire harness at Main PBA CN600 and Sub PBA CNS200
- 2
Verify harness is completely connected
- 3
Check Main-Sub PBA software version via HASS
This Error Applies To
Samsung DOB30P977D Series Ovens & Ranges (2020) (2020–present)
Related Error Codes
Oven temperature control failure causing excessive heating
Temperature probe sensor short circuit detected
Steam temperature sensor open circuit detected
Drain pump failure or water sensor malfunction in steam system
A control button is stuck in pressed position
Cooling fan motor failure
PCB internal temperature sensor open circuit
Steam temperature sensor short circuit