Error Code C-d0
Short key — short circuit detected at control interface at connector CN300 on Main PCB or Sub PCB
Moderate
Address soon - your appliance may not work properly
What This Means
Wire harness not properly inserted into connector of Main PCB or Sub PCB; Short circuit between Main PCB connector CN300 pins
How to Fix
- 1
Disconnect power
- 2
Check whether connector CN300 pins are shorted
- 3
Check if wire harness is properly inserted into connector of Main PCB or Sub PCB
- 4
Repair the short circuit between connector CN300 pins on Main PCB
- 5
Check if pattern between Micom and connector is shorted or damaged
- 6
Replace or repair PCB if needed
This Error Applies To
Samsung DOP36M96GL Series Ovens & Ranges (2019) (2019–present)
Related Error Codes
PCB sensor temperature high — onboard PCB NTC thermistor reading abnormally high temperature
Door locking information — door lock motor or switch malfunction
Oven sensor open (over 2950 ohm) or oven sensor short (under 930 ohm)
Oven internal overheating — oven temperature reaches 650 F (343 C) in any cooking function except self-clean
PCB sensor opened or PCB sensor shorted (onboard NTC thermistor fault)
Main PCB to Sub PCB communication error