Error Code GAS_LEAK
Active gas leak in system
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: Gas leak detected
What This Means
Gas pipes not assembled on correct position; Burst or crack in gas line; Valve gasket or manifold installed incorrectly; Leaking connection at burner valve
What actually causes this:
Loose connection, cracked line, or improper assembly
First Thing to Check
Evacuate and shut off gas supply immediately
Parts Involved
How to Fix
- 1
SAFETY: Evacuate building immediately and call gas supplier from neighbor's phone
- 2
Turn off cooktop valve and main shut off valve
- 3
Check if gas smell remains after valves closed
- 4
If no smell, check gas pipe on bottom side is properly assembled
- 5
Check each burner valve one at a time for leaks using soapy water on all connections
- 6
Check for crimped or broken gas pipe
- 7
Check if valve gasket/manifold was installed correctly
This Error Applies To
Samsung DTT48T963 Series Ovens & Ranges (2022) (2022–present)
Related Error Codes
Single knob backlight circuit failure
Loss of wireless communication between hood and cooktop
Re-ignition module failure or electrical ground problem
Flame color indicates improper gas-to-air mixture
Flame quality degradation due to assembly or pressure issues
WiFi/Bluetooth connectivity not established
Single burner ignition system failure
Complete loss of burner ignition capability