Samsung Ovens & Ranges
Error Code C-30
PCB temperature sensor opened
Moderate
Address soon - your appliance may not work properly
What This Means
PCB temperature sensor circuit is open; Disconnected or damaged sensor wiring; Faulty PCB temperature sensor
How to Fix
- 1
Disconnect power and open back cover
- 2
Remove PCB Main from holder
- 3
Measure PCB temperature sensor resistance (should be 1.5-3 kohms at normal conditions)
- 4
Check for any problems and replace PCB Main if issues found
This Error Applies To
Samsung NE59J7630S Series Ovens & Ranges
Service manual exact match: NE59N6630SS/AAService manual exact match: NE59J7630SSService manual exact match: NE59N6630SS