Samsung Ovens & Ranges
Error Code C-A2
Sub PCB temperature abnormally high
Moderate
Address soon - your appliance may not work properly
What This Means
Cooling vent blocked; Excessive ambient temperature; Thermal sensor failure
How to Fix
- 1
Press OFF
- 2
Check oven vent and cooling vent for blockage
- 3
Do not block any vents
- 4
Allow oven to cool
- 5
Restart oven
- 6
If problem persists, call for service
This Error Applies To
Samsung NE63T8951 Series Ovens & Ranges
Service manual exact match: NE63T8951
Related Error Codes
C-21
Oven heating over - abnormal temperature rise
C2
IGBT sensor open or short circuit
C-20
Oven sensor opened (over 2950Ω) or oven sensor shorted (under 930Ω)
C-22
Sub PCB sensor open circuit
C-23
Temperature probe sensor short circuit
C-30
Main PCB sensor open circuit
-dC-
Divider inserted or removed while oven operating
bAd LInE
Power cord installed improperly