Samsung Ovens & Ranges2020–present

Error Code C-70

Steam sensor is open or shorted when steam mode is on

Moderate

Address soon - your appliance may not work properly

What This Means

Sensor connector not inserted at main PCB; Sensor connector not inserted at sensor; Temperature sensor failure; Main PCB failure

How to Fix

  1. 1

    Check whether connector at the main PCB has been inserted

  2. 2

    Check whether connector at the sensor has been inserted

  3. 3

    Replace the temperature sensor if connectors are correct

  4. 4

    Replace the Main PCB if problem persists

This Error Applies To

Samsung NV51K6650 Series Ovens & Ranges (2020) (2020–present)

Service manual exact match: NV51K6650S*Service manual exact match: NV51K6650D*