Samsung Ovens & Ranges

Error Code C-72

Drain system problem - Water level sensor detects water remaining after max draining time

Moderate

Address soon - your appliance may not work properly

What This Means

Ground wire on steam generator disconnected; Pump motor not operating; Wire connection faulty; Main PCB failure

How to Fix

  1. 1

    Check ground wire on steam generator is connected

  2. 2

    Check pump motor operation and wire connections

  3. 3

    If problem persists, replace Main PCB

This Error Applies To

Samsung NV51K7770D Series Ovens & Ranges

Service manual exact match: NV51M9970DService manual exact match: NV51M9770DService manual exact match: NV51K7770DG