Error Code TCO Open
Thermal Cutoff Device Open
Moderate
Address soon - your appliance may not work properly
What This Means
Excessive temperature rise; Main power loss during operation causing temporary temperature spike; Defective TCO device; Sensor malfunction; Motor or fan failure
How to Fix
- 1
Replace TCO device
- 2
Check wire short and sensor operation
- 3
Check cooling motor and convection motor operation
- 4
Verify motor connector is properly connected
- 5
Check motor resistance: Cooling motor 238Ω, Convection motor 218Ω
- 6
Check motor terminal voltage
- 7
Check PCB SMPS input voltage (5V, 230V)
- 8
Check PCB SMPS output voltage (5V, 12V)
- 9
Check PCB relay contact for short
- 10
Replace motor if resistance and voltage checks fail
- 11
Replace PCB if all other components are functional
This Error Applies To
Samsung NV75N7546R Series Ovens & Ranges (2020) (2020–present)