Error Code C-70
Steam sensor open or short during steam mode operation
Moderate
Address soon - your appliance may not work properly
What This Means
Steam sensor connector not inserted; Temperature sensor malfunction; Water level sensor failure; Main PCB failure
How to Fix
- 1
Check whether connector at Main PCB properly inserted
- 2
Check whether connector at sensor properly inserted
- 3
Verify water level sensor connected correctly between Wall Main PCB (CN340) and Bowl water sensor
- 4
Replace temperature sensor if connectors normal
- 5
Replace Main PCB if sensor replacement unsuccessful
- 6
Reconnect all harnesses
This Error Applies To
Samsung NY36R9966P Series Ovens & Ranges
Related Error Codes
Drain system failure - water remained after max draining time
Oven sensor open (over 2950Ω) or Oven sensor short (under 930Ω)
Oven heating over (temperature exceeds acceptable range)
Temperature probe sensor issue (open or short when oven operating)
Main to touch panel communication interrupted
Cooling motor operating abnormally
PCB sensor opened or shorted
Short key (keyboard/control input short circuit)