Error Code C-A2
Cooling motor operating abnormally
Moderate
Address soon - your appliance may not work properly
What This Means
Cooling motor connector not inserted; Hall sensor PCB failure; Wire connection incorrect between Wall Main PCB and motor; Main PCB failure
How to Fix
- 1
Check whether connector at Main PCB properly inserted
- 2
Check whether connector at cooling motor properly inserted
- 3
Verify wire correctly connected between Wall Main PCB (CN202) and Motor connector
- 4
Check Hall sensor PCB connection (refer to pin map)
- 5
Replace Hall sensor PCB if needed
- 6
Replace cooling motor if problem persists
- 7
Replace Wall Main PCB if necessary
This Error Applies To
Samsung NY36R9966P Series Ovens & Ranges
Related Error Codes
Drain system failure - water remained after max draining time
Oven sensor open (over 2950Ω) or Oven sensor short (under 930Ω)
Oven heating over (temperature exceeds acceptable range)
Temperature probe sensor issue (open or short when oven operating)
Main to touch panel communication interrupted
Steam sensor open or short during steam mode operation
PCB sensor opened or shorted
Short key (keyboard/control input short circuit)