Samsung Refrigerators2013–present

Error Code 44Er

Main board can't communicate with compressor inverter

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 44Er displayed on panel

What This Means

Inverter communication cable disconnected or loose; Inverter PCB defect; Main PCB defect; Wire harness damage; Compressor inverter module failure

What actually causes this:

Inverter cable disconnected or compressor control board failed

First Thing to Check

Check if compressor is running

Parts Involved

Inverter BoardMain PCBCompressor Inverter ModuleCommunication cable

How to Fix

  1. 1

    1. Check inverter communication cable connectors

  2. 2

    2. Verify cable is fully seated on both ends

  3. 3

    3. Inspect for visible wire damage

  4. 4

    4. Use oscilloscope to verify signal integrity

  5. 5

    5. If cable is normal, replace Main PCB or Inverter PCB

  6. 6

    6. May require inverter module replacement

This Error Applies To

Samsung RF23HCED Series Refrigerators (2013) (2013–present)

Service manual exact match: RF23HCEDTSRService manual exact match: RF23HCEDBSRService manual exact match: RF23HCEDBBCService manual exact match: RF23HCEDBWW