Error Code COMP-START-FAIL
Compressor will not start
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: LED blinks
What This Means
Short circuit between compressor U,V,W phases; Inverter IPM failure (pins 1-33 shorted); DC voltage below 13.5V; Compressor mechanical jam
What actually causes this:
Low voltage or inverter circuit failure
First Thing to Check
Check wall outlet voltage and power cord connection
Parts Involved
How to Fix
- 1
1. Check for short between compressor terminals on CN04
- 2
2. Measure IPM voltage (must be above 13.5V)
- 3
3. Check for solder bridges or shorts on inverter PCB
- 4
4. Verify compressor mechanical condition and refrigerant cycle
This Error Applies To
Samsung RF24R7201 Series Refrigerators (2010) (2010–present)
Related Error Codes
Freezer temperature sensor not working
Outdoor temperature sensor not working
Ice storage compartment temperature sensor not working
Freezer defrost heater not heating
Ice room fan not running
Water/ice dispenser panel not communicating
Fridge temperature sensor not working
Flex Zone drawer temperature sensor not working