Error Code COMP-IPM-SHUTDOWN
Compressor power module overheated
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: COMP-IPM-SHUTDOWN LED blinks
What This Means
IPM module overheating; Solder joint cracks on inverter; DC 15V output less than 13.5V; Compressor stall or short
What actually causes this:
Inverter overheated or insufficient power supply voltage
First Thing to Check
Check if inverter feels hot, allow to cool
Parts Involved
How to Fix
- 1
Check IPM heatsink temperature
- 2
Verify DC 15V output voltage
- 3
Inspect inverter PCB solder
- 4
Check compressor and cycle
This Error Applies To
Samsung RF28R7201 Series Refrigerators (2010) (2010–present)
Related Error Codes
Fridge cooling fan malfunction
Flex zone temperature control heater failure
Ice maker not making ice
Main board input/output chip failure
Ice room fan not operating
Dispenser display not communicating
Compressor control board communication failed
Ice storage compartment heater failure