Error Code COMP-LOCATION
Compressor position sensor signal lost
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: COMP-LOCATION LED blinks
What This Means
Compressor wiring loose; Compressor resistance measurements wrong; Inverter PCB solder defects; Compressor mechanical failure
What actually causes this:
Compressor connection loose or inverter failed
First Thing to Check
Check if compressor connector is seated fully
Parts Involved
How to Fix
- 1
Verify compressor connector tight
- 2
Measure R2 resistance [0.09 Ohm]
- 3
Inspect main PCB solder quality
- 4
Test compressor
This Error Applies To
Samsung RF28R7201 Series Refrigerators (2010) (2010–present)
Related Error Codes
Fridge cooling fan malfunction
Flex zone temperature control heater failure
Ice maker not making ice
Main board input/output chip failure
Ice room fan not operating
Dispenser display not communicating
Compressor control board communication failed
Ice storage compartment heater failure