Error Code 10
Compressor power control module failure
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 82
What This Means
IPM semiconductor failure; Inverter circuit short circuit; Solder joint failure; Thermal stress on IPM device; Voltage spike damage
What actually causes this:
Inverter board failed from power surge or age
First Thing to Check
Check if inverter PCB LED is lit during operation
Parts Involved
How to Fix
- 1
Check inverter PCB for thermal damage or burnt components
- 2
Verify solder joints around IPM device
- 3
Check for short circuits in inverter output stage
- 4
Measure gate drive signals to IGBT transistors
- 5
Test with forced operation
This Error Applies To
Samsung RR39M73 Series Refrigerators
Related Error Codes
External humidity sensor reading is out of range
Cooling fan motor is not operating properly
Fridge room temperature sensor is malfunctioning
Freezer defrost temperature sensor malfunction detected
Freezer defrost cycle cannot complete properly
House electrical supply voltage too high
Smart home WiFi connectivity lost
Condenser fan motor not operating when required