Samsung Refrigerators

Error Code 44Er

Compressor inverter control board not communicating with main control

Moderate

Address soon - your appliance may not work properly

Also displayed as: 44Er on panel

What This Means

Inverter to Main communication line issue; Inverter PCB communication failure; Main PCB communication chip failure; Loose or damaged communication cable; Inverter power supply failure

What actually causes this:

Communication cable between inverter and main board loosened or failed, preventing compressor speed control

First Thing to Check

Reseat the communication cable between main PCB and inverter

Parts Involved

Main PCBInverter PCBCommunication cable/connector

How to Fix

  1. 1

    Check communication cable between Main and Inverter PCB

  2. 2

    Verify Inverter PCB is powered

  3. 3

    Inspect connector pins for damage or corrosion

  4. 4

    Test cable continuity

  5. 5

    Check for swollen capacitors on Inverter board

This Error Applies To

Samsung RS22R5561 Series Refrigerators

Service manual exact match: RS22R5561Service manual exact match: RS27T5561Service manual exact match: RS22T5200Service manual exact match: RS22T5201Service manual exact match: RS28T5B00Service manual exact match: RS22T5561Service manual exact match: RS27T5200