Error Code tC1
The water temperature sensor is not reading correctly
Moderate
Address soon - your appliance may not work properly
Also displayed as: tC1
What This Means
Washing heater sensor contact error or temperature sensor fault; Connector is connected incorrectly or is disconnected; Water level sensor operates without water (frozen conditions) and bottom overheat sensor detects 100–150°C; Faulty temperature sensor
What actually causes this:
The temperature sensor wire came loose, or the sensor itself went bad
First Thing to Check
Unplug the washer, wait a minute, and plug it back in — if the error returns, it needs service
Parts Involved
How to Fix
- 1
1. Check the temperature sensor connector — verify it is connected correctly and not disconnected
- 2
2. Check for frozen water conditions that could cause the sensor to operate without water
- 3
3. Measure the temperature sensor resistance
- 4
4. If the sensor is faulty, replace it
This Error Applies To