Error Code TC7
A temperature sensor on the evaporator inlet is reading incorrectly
Moderate
Address soon - your appliance may not work properly
Also displayed as: TC7
What This Means
EVA In thermistor resistance out of range; Connector disconnected
What actually causes this:
The evaporator inlet temperature sensor lost its connection or failed
First Thing to Check
Unplug and replug the washer — if the error persists, it needs service
Parts Involved
How to Fix
- 1
1. Check the resistance of the EVA In thermistor — should be 10 kOhm plus or minus 3% at 25 degrees C
- 2
2. Check the connection of the connector
This Error Applies To
Samsung WD53DBA900HZA1 Series Washers (2024) (2024–present)
Related Error Codes
A dryer button is being registered as stuck or continuously pressed
The heat pump compressor motor has failed or lost its connection
A temperature sensor on the refrigerant line is reading incorrectly
A temperature sensor on the evaporator outlet is reading incorrectly
A temperature sensor on top of the compressor is reading incorrectly
The dryer heater temperature sensor is reading incorrectly
The humidity sensor inside the dryer is not reading correctly
The door lock has been forced too many times and is malfunctioning