Quick RefFurnace Error Codes by Brand
LED blink codes for Carrier, Trane, Rheem, Goodman, and Lennox furnaces. What they mean and what to do.
Before You Look Up Codes#
- Check and replace your air filter first
- Make sure vents aren't blocked
- Verify gas supply is on
Carrier / Bryant / Payne#
| Blinks | Meaning | Action |
|---|---|---|
| Steady ON | Normal standby | None needed |
| 1 | Ignition failure | Reset power, call if persists |
| 2 | Pressure switch stuck open | Check vents for blockage |
| 3 | Limit switch open | Replace filter! Check airflow |
| 4 | Pressure switch stuck closed | Call technician |
| 6 | Reversed polarity | Call electrician |
Trane / American Standard#
| Blinks | Meaning | Action |
|---|---|---|
| Slow steady | Normal | None needed |
| 2 | Ignition/flame sensor | Call technician |
| 3 | Pressure switch | Check vents for blockage |
| 4 | Overheating | Replace filter! |
| 5 | Gas valve issue | Call technician |
Rheem / Ruud#
| Blinks | Meaning | Action |
|---|---|---|
| 1 | Soft lockout | Will retry automatically |
| 2 | Pressure switch open | Check vents |
| 3 | Limit switch open | Replace filter! |
| 4 | Pressure switch stuck | Call technician |
Goodman / Amana#
| Blinks | Meaning | Action |
|---|---|---|
| Constant | Reversed polarity | Call electrician |
| 1 | Ignition lockout | Reset, call if persists |
| 2 | Pressure switch open | Check vents |
| 3 | Pressure switch stuck | Call technician |
| 4 | Limit/rollout switch | Replace filter, call if persists |
Lennox#
Lennox uses two LEDs (red and green). Both flashing slowly together = normal operation. Check the code chart inside your furnace panel for specific patterns.
Universal Reset Procedure#
- Turn off furnace power (switch or breaker)
- Wait 20-30 seconds
- Turn power back on
- If code returns, call a technician