Error code

C-31

Meaning

PCB sensor temperature high — onboard PCB NTC thermistor reading abnormally high temperature

Moderate

What to do

Why this happens

Possible causes include a PCB NTC thermistor failure or a faulty oven temperature sensor leading to runaway conditions.

SourceSamsung service manual

Other error codes for DOP36M96GLS

C-F0

Main PCB to Sub PCB communication error

C-d0

Short key — short circuit detected at control interface at connector CN300 on Main PCB or Sub PCB

C-21

Oven internal overheating — oven temperature reaches 650 F (343 C) in any cooking function except self-clean

C-30

PCB sensor opened or PCB sensor shorted (onboard NTC thermistor fault)

C-d1

Door locking information — door lock motor or switch malfunction

C-20

Oven sensor open (over 2950 ohm) or oven sensor short (under 930 ohm)