Error Code C-23
Meat probe sensor is shorted when oven is operating
Moderate
Address soon - your appliance may not work properly
What This Means
Probe harness shorted; Defective probe sensor; Damaged connector terminals
How to Fix
- 1
Disconnect power
- 2
Disconnect probe harness from control board
- 3
Measure probe resistance (normal 50 kilo-ohms at room temp)
- 4
Check wire harness and connector terminals for damage
- 5
Check probe connector resistance on Main PCB (normal 10-11 kilo-ohms)
- 6
Replace meat probe if resistance is incorrect