Error Code C-70
Steam sensor is open or shorted during steam mode
Moderate
Address soon - your appliance may not work properly
What This Means
Water sensor harness disconnected; Defective water level sensor; Loose sensor connector
How to Fix
- 1
Disconnect power
- 2
Check Main PCB connector CN340 connection
- 3
Check water sensor connector connection
- 4
Measure sensor resistance if applicable
- 5
Replace temperature sensor if connectors are ok
- 6
Replace Main PCB if problem still not solved