Error Code C-72
Drain system failure - water remained after max draining time
Moderate
Address soon - your appliance may not work properly
What This Means
Ground wire disconnected on steam generator; Pump motor failure; Water sensor malfunction; Main PCB failure
How to Fix
- 1
Check ground wire on steam generator connection
- 2
Check pump motor operation and wire connection
- 3
Verify water level sensor functionality
- 4
Replace Wall Main PCB if needed
- 5
Reconnect all harnesses
- 6
Change pump motor if necessary
- 7
Replace Main PCB if problem persists
Other Error Codes for NX58M9960P
Temperature probe sensor issue (open or short when oven operating)
Main to touch panel communication interrupted
Steam sensor open or short during steam mode operation
PCB around temperature high (safety error)
Oven sensor open (over 2950Ω) or Oven sensor short (under 930Ω)
Oven heating over (temperature exceeds acceptable range)
Cooling motor operating abnormally
PCB sensor opened or shorted