Error Code E FF
Defect of BLDC fan motor for freezer
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Reset the unit. Enter Test Mode 1 (push test button 1 time).
- 2
Measure Fan Motor voltage at CON4 pins 20th~19th. Should be 11.4~12.6V.
- 3
If voltage is NOT 11.4~12.6V: replace Main PCB.
- 4
If voltage is correct: open freezer door and check for airflow. If windy: go to step 5.
- 5
If not windy: check fan motor physically - rotate fan by hand. If fan feels sticky/seized: replace fan motor.
- 6
Step 5 - Check fan feedback voltage at CON4 pins 18th~19th. Should be not 0 or 5V (variable). If voltage is 0 or 5V only: replace the fan motor.
- 7
Step 6 - Check fan PWM voltage at CON4 pins 17th~19th. Should be not 0 or 5V. If voltage is 0 or 5V only: replace Main PCB.
- 8
If all checks pass: explain to customer.