Ice maker not working
Parts commonly needed when your LG refrigerator has this issue. Recommendations are based on repair patterns and may not diagnose your specific problem.
Verified Components
Parts
2Part numbers confirmed across multiple retailers for LRMVC2306S
Repair tips for this issue
From the service manual for LG LRMVS3006D Series Refrigerators (2020)
From the service manual
Good to know
5 technician insights for the LG LRMVS3006D Series Refrigerators (2020)
Low-Side Leak Repair
When a low-side refrigerant leak is found, moisture from air has almost certainly entered the system (low side is below atmospheric pressure during a leak). Replace both the leaking part AND the compressor, plus install a new drier — failure to replace the compressor risks carbonization of compressor oil.
Pressure Diagnosis
For E CH/CL sealed system diagnosis: equalization time under 5 minutes is normal. 5~15 minutes is borderline. Over 15 minutes confirms restriction. Equalization pressure above 40 psi with a long equalization time points to compressor failure, not a leak.
Sealed System
Install a UV (dye) drier after any sealed system repair where the leak location was difficult to find. The fluorescent material circulates with oil and refrigerant, allowing UV light and goggles to detect the precise leak point on a follow-up visit.
Water System
High water supply pressure from the shutoff valve can cause water to overshoot the fill cup into the ice bin, resulting in clumped ice. If the customer reports water flooding the ice bin, check supply pressure and recommend a pressure regulator or partially closing the shutoff valve.
Seeing an error code on your display? Look up your error code → for more specific diagnostic information.