Error Code E FS
Defect of freezer sensor
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Check CON8 22nd-to-21st-pin: if reading is 0 Ω the sensor is shorted — replace freezer sensor.
- 2
Check CON8 22nd-to-21st-pin: if reading is OL/open — go to step 3.
- 3
Check sensor resistance against temperature table (e.g., 8 kΩ at 32°F / 0°C, 10 kΩ at 23°F / -5°C, 13 kΩ at 14°F / -10°C, 17 kΩ at 5°F / -15°C, 23 kΩ at -4°F / -20°C, 30 kΩ at -13°F / -25°C, 40 kΩ at -22°F / -30°C). If resistance is out of range, replace sensor.
- 4
If resistance is in range, check connector between Main PCB and sensor for loose/disconnected condition — reconnect or repair.
- 5
If connector is OK, check sensor wiring harness continuity.
- 6
If all wiring and connector checks pass and error persists, explain to customer (intermittent contact) or replace refrigerator main PCB.
Other Error Codes for LRYKC2606S
Defect of freezer craft ice maker sensor
Defect of ice maker kit (in-door icemaker motor malfunction)
Defect of Mini Cubed ice maker kit
Defect of UVC LED / PSD sensor
Defect of flow meter / lack of water supply
PSD sensor error
Defect of refrigerator sensor
Defect of BLDC fan motor for machine room (condenser fan)