Error Code E iS
Defect of ice-room or ice maker sensor
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Check CON3 10th-to-9th-pin: if 0 Ω, sensor shorted — replace ice-room sensor.
- 2
If OL/open — go to step 3.
- 3
Check sensor resistance against temperature table (40 kΩ at -22°F, 30 kΩ at -13°F, 23 kΩ at -4°F, 17 kΩ at 5°F, 13 kΩ at 14°F, 10 kΩ at 23°F, 8 kΩ at 32°F). If out of range, replace sensor.
- 4
Check connector between Main PCB and ice-room sensor — reconnect or repair.
- 5
If connector OK and error persists, explain to customer or replace Main PCB.
Other Error Codes for LRYKC2606S
Defect of freezer craft ice maker sensor
Defect of ice maker kit (in-door icemaker motor malfunction)
Defect of Mini Cubed ice maker kit
Defect of UVC LED / PSD sensor
Defect of flow meter / lack of water supply
PSD sensor error
Defect of refrigerator sensor
Defect of BLDC fan motor for machine room (condenser fan)