Error Code 29C
Cool Select Room defrost heater failed
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 29C
What This Means
Heater housing separation; Contact error; Wire disconnection; Short-circuit in heater; Blown temperature fuse
What actually causes this:
Defrost heater circuit broken or fuse blown
First Thing to Check
Check if Cool Select heater has AC power
Parts Involved
How to Fix
- 1
Separate MAIN PCB CN70 wire from PCB
- 2
Check resistance between CN70 pin #3 and #1
- 3
If 0 Ohm, check for short-circuit
- 4
If ∞ Ohm, check for open-circuit