Error Code 13E

Humidity sensor output voltage failure

Minor

Usually easy to fix - may resolve on its own

Also displayed as: 13 E

What This Means

Separation of sensor housing part; Contact error or disconnection; Short circuit in sensor circuit

What actually causes this:

Disconnected humidity sensor, internal sensor failure, or wire break in humidity circuit

First Thing to Check

Check that humidity sensor is properly inserted into CN30 housing

Parts Involved

Humidity Sensor (DA32-00034B)Connector CN30

How to Fix

  1. 1

    Check voltage between MAIN PCB CN30 #7 and #9, should be 4.5V to 1.0V

  2. 2

    Verify humidity sensor is properly seated in CN30

  3. 3

    Check voltage supply to sensor (#1-#2) is about 5V

  4. 4

    Check output voltage (#3) is between 1-4V

Need more help with your Samsung RH25H5611BC?