Error Code TC1
The washer's water temperature sensor is not reading correctly.
Moderate
Address soon - your appliance may not work properly
Also displayed as: TC1
What This Means
Washing heater sensor in tub has a contact or temperature sensor fault; Connector connected incorrectly or disconnected; Water level sensor operates without water (frozen) and temperature sensor detects 100-150°C, triggering power off; Faulty and incorrect connections; Washing heater temperature sensor has a functional error; Freezing in winter season
What actually causes this:
The temperature sensor plug has come loose from its connector on the main board.
First Thing to Check
Unplug the washer for 5 minutes and plug it back in. If the error returns, the sensor needs service.
Parts Involved
How to Fix
- 1
1. Check the washing temperature sensor connections and connector
- 2
2. Check the dry temperature sensor connections and connector
- 3
3. If the washing heater temperature sensor has a functional error, replace it
- 4
4. If the dry heater temperature sensor has a functional check, replace it
- 5
5. Check main PCB fault
Other Error Codes for WA50K8600AV
The washer's temperature sensor is giving wrong readings.
A specific internal water leak has been found.
There are too many soap suds in the washer.
The washer's vibration sensor board has a problem.
The washer's clutch position sensor is sending incorrect signals.
The washer's main computer chip has crashed.
The washer cannot detect how much water is in the tub.
The washer's motor cannot spin or is getting bad signals.