Error Code dE
Door switch abnormal
Moderate
Address soon - your appliance may not work properly
Also displayed as: dE
How to Fix
- 1
Enter diagnostic test mode.
- 2
Press START/PAUSE once to start tumbling without heat.
- 3
Open the door — dE should display and chime should sound 7 times and drum light should illuminate (if equipped).
- 4
If dE does not display or drum light does not come on, proceed to mechanical test.
- 5
Disconnect WH1 and BL3 connectors from main PCB.
- 6
Measure resistance between NA6 pin (GN) and chassis ground screw — should be less than 1 Ω.
- 7
If resistance is not less than 1 Ω, check all wiring harness connections and ground screws.
- 8
If ground is good, disconnect BL2 and WH4 connectors from main PCB.
- 9
Measure resistance between BL2 (WH wire) and WH4 (YL wire) — should be less than 1 Ω with door closed and infinite (open) with door open.
- 10
If resistance values are reversed or incorrect, replace the door switch.
- 11
If resistance values are correct, replace the main PCB.
- 12
For drum light circuit: disconnect WH4 and black tab relay connectors from main PCB. Measure resistance between WH4 YL and WH4 BK — should be less than 1 Ω with door open and infinite with door closed.
- 13
If drum light circuit fails, replace light bulb first, then light socket if bulb replacement does not resolve.
Other Error Codes for DLE3600B
NFC module open or shorted
Exhaust ductwork approximately 95%+ blocked - FlowSense alert
Water supply pump failure - pump AD value below 10 in test mode
Exhaust ductwork approximately 90-95% blocked - FlowSense alert
Thermistor of steam generator - open or shorted
NFC module type is wrong
EE PROM (non-volatile memory) operation is abnormal
No power / power supply issue - electric dryer power cord not connected or house power supply incorrect