Error Code HS
Humidity sensor failure
Moderate
Address soon - your appliance may not work properly
Also displayed as: HS
How to Fix
- 1
Turn off the dryer.
- 2
Inspect moisture sensor bars inside lint filter housing for contamination or damage.
- 3
Check wiring harness between sensor bars and main PCB (connector WH6) for damage.
- 4
Measure resistance between WH6 (GN) pin and chassis ground; should be less than 1Ω.
- 5
Disconnect WH6 connector from main PCB; jumper WH6 pin (OR) to WH6 pin (BL).
- 6
Measure resistance between the two sensor bars; should be less than 1Ω with jumper in place.
- 7
If not, check all connections and wires between WH6 terminal at main PCB and sensor bars.
- 8
If wiring is intact but fault persists, call for service.