Error Code d80
FlowSense indicator — ductwork restriction detected, displayed after drying cycle ends
Moderate
Address soon - your appliance may not work properly
What This Means
Ductwork is too long or has too many turns/restrictions; Significant blockage from lint buildup or debris; Restriction in the external dryer venting
How to Fix
- 1
Dryer can be used in this condition but drying times may be longer
- 2
Check and clean ductwork soon
- 3
If FlowSense restrictions are sensed, indicator will remain on for two hours after end of cycle
- 4
Opening the door or pressing POWER button will turn off the display
- 5
Install a shorter or straighter duct run per installation instructions
Other Error Codes for DLEX7600KE
Door switch abnormal (only displayed in test mode)
Thermistor of steam generator open or shorted
EEPROM error — only displayed in test mode
Pump error (steam models)
No Power — same root causes as PS/PF
Thermistor of blower housing open or shorted (same sensor as tE1, displayed in drying cycle or test mode)
Humidity Sensor failure
Power Failure