Error Code dE
Door switch abnormal (only displayed in test mode)
Moderate
Address soon - your appliance may not work properly
What This Means
Door switch is abnormal; Door not fully closed
How to Fix
- 1
Error only displayed in TEST MODE
- 2
Perform door switch test (Test 5)
- 3
Measure resistance at BL2 and BK2/WH1 connectors
- 4
Door closed: resistance between BL2-pin1 (White) and BK2-pin2 (Black) should be below 2500 ohms
- 5
Door open: resistance between BL2-pin1 and BK2-pin2 should be 300-60 ohms
- 6
If out of range, check lamp and door switch
- 7
Replace door switch if faulty
Other Error Codes for DLEX7600KE
Ductwork approximately 90-95% blocked (displayed for 2 hours only)
Ductwork approximately 95% blocked (displayed for 2 hours only)
FlowSense indicator — ductwork restriction detected, displayed after drying cycle ends
Humidity Sensor failure
Power Failure
Thermistor of blower housing open or shorted
Thermistor of steam generator open or shorted
EEPROM error — only displayed in test mode