Error Code tE1
Thermistor of blower housing open or shorted
Moderate
Address soon - your appliance may not work properly
What This Means
Thermistor open circuit; Thermistor short circuit; Harness connection to NA6 connector loose or disconnected
How to Fix
- 1
Turn off power and discharge voltage by contacting metal plug of power cord to ground
- 2
Remove NA6 connector from controller
- 3
Short Pin 1 (Blue Wire) and Pin 4 (Orange Wire) to controller — if short is detected, check control and 6-pin connector are properly connected, then replace controller
- 4
If no short detected, measure resistance between thermistor assembly terminals after separating harness
- 5
Compare measured resistance to temperature table (e.g., 50F=18kOhm, 70F=9.3kOhm, 90F=7.7kOhm)
- 6
If resistance is out of range, replace thermistor
- 7
If resistance is in range, check harness-linking connector