Error Code PS
Power supply wire connection wrong or loose (electric dryer)
Moderate
Address soon - your appliance may not work properly
Also displayed as: PS
How to Fix
- 1
Verify power cord wiring: Black wire to L1, White wire to Neutral (center), Red wire to L2.
- 2
Check that all terminal block nuts are tight and power cord is in correct position.
- 3
Check voltage at outlet: should be 208–240VAC between L1 and L2.
- 4
Reset circuit breaker or replace fuse if blown; do not increase fuse capacity.
- 5
If power supply is correct, check for loose or crossed connections at terminal block.
- 6
Refer to Section 3-1 Connecting Electric Dryers for complete wiring instructions.
- 7
If connections are correct and error persists, replace the main PCB.
Other Error Codes for DLGX4371B
Ductwork approximately 90% blocked
Outlet thermistor open or shorted (second thermistor)
NFC module open or shorted
Ductwork approximately 80% blocked
Steam generator thermistor open or shorted
Power failure or incorrect power supply
NFC module wrong or unresponsive
Ductwork approximately 75% blocked