Error Code tE1
Outlet thermistor open or shorted
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE1
How to Fix
- 1
Turn off the dryer power.
- 2
Remove connector NA6 from the controller.
- 3
Short pin 2 (Blue Wire) and pin 3 (Orange Wire) with a metal jumper.
- 4
If tE1 clears, check that NA6 connector and 6-pin connector are securely connected to controller; if connection is good, replace controller.
- 5
If tE1 persists, measure resistance between thermistor terminals with harness disconnected; compare to Table 1 (50°F/10°C = 18.0kΩ, 70°F/27°C = 9.3kΩ, 100°F/38°C = 6.2kΩ, 130°F/54°C = 2.9kΩ, 160°F/71°C = 2.2kΩ).
- 6
If resistance is out of range, replace thermistor.
- 7
If resistance is in range, check harness linking connector for corrosion, bent pins, or broken wires and repair as needed.
Other Error Codes for DLGX4371V
Ductwork approximately 90% blocked
Outlet thermistor open or shorted (second thermistor)
Power supply wire connection wrong or loose (electric dryer)
NFC module open or shorted
Ductwork approximately 80% blocked
Steam generator thermistor open or shorted
Power failure or incorrect power supply
NFC module wrong or unresponsive