Error Code tE2
Outlet thermistor open or shorted (second thermistor)
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE2
How to Fix
- 1
Turn off the dryer power.
- 2
Remove connector NA6 from the controller.
- 3
Short pin 2 (Blue Wire) and pin 3 (Orange Wire) with a metal jumper.
- 4
If tE2 clears, verify NA6 and 6-pin connector are properly connected; if good, replace controller.
- 5
If tE2 persists, disconnect harness from thermistor assembly connector and measure resistance between terminals.
- 6
Compare measured resistance to Table 1; if out of range, replace thermistor.
- 7
If resistance is in range, check harness linking connector for damage and repair.
Other Error Codes for DLGX4371V
Ductwork approximately 90% blocked
Power supply wire connection wrong or loose (electric dryer)
NFC module open or shorted
Ductwork approximately 80% blocked
Steam generator thermistor open or shorted
Power failure or incorrect power supply
NFC module wrong or unresponsive
Ductwork approximately 75% blocked