Error Code dE
Door switch abnormal
Moderate
Address soon - your appliance may not work properly
Also displayed as: dE
How to Fix
- 1
Activate diagnostic test mode: press POWER while pressing MORE TIME and LESS TIME simultaneously.
- 2
dE error only appears in test mode.
- 3
Turn power off and discharge voltage.
- 4
With door closed, measure resistance between BL2-3 (White wire) and BK2-3 connector after removing BL2 and WH4 from controller; expect below 2500Ω.
- 5
With door open, measure resistance between BL2-3 (White wire) and BK2-3 (Black wire); expect 300–600Ω.
- 6
With door open, measure resistance between WH4-2 (Yellow wire) and BL2-3 (White wire); expect below 10Ω.
- 7
With door closed, measure resistance between WH4-2 (Yellow wire) and BL2-3 (White wire); expect below 10Ω.
- 8
Check door switch per component testing procedures (COM-NC terminals).
- 9
Check lamp — if door lamp is faulty it can affect door circuit; replace lamp and re-measure.
- 10
If all switch measurements pass, check controller and harness-linking connectors.
- 11
Replace door switch if COM-NC(1-3) does not read below 12Ω when door knob is open.