Error Code tE1
Thermistor of blower housing open or shorted
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE1
How to Fix
- 1
Enter diagnostic test mode: press POWER while pressing MORE TIME and LESS TIME simultaneously.
- 2
If tE1 appears, thermistor is open or shorted.
- 3
Turn power off and discharge voltage (contact metal plug of power cord with ground).
- 4
Remove NA6 connector from controller.
- 5
Short Pin 4 (Blue Wire) and Pin 5 (Orange Wire) together with a metal wire.
- 6
If controller now responds correctly, check that NA6 connector and 6-pin connection to controller are properly connected; replace controller if not.
- 7
If controller does not respond after shorting, remove harness from thermistor assembly connector and measure resistance.
- 8
Compare resistance to Table 1: at 50F/10C expect 18.0kΩ, at 70F/21C expect 11.7kΩ, at 90F/32C expect 7.7kΩ, at 110F/43C expect 5.2kΩ, at 130F/54C expect 2.9kΩ.
- 9
If resistance is out of range, replace thermistor assembly.
- 10
If resistance is in range, check harness-linking connector for continuity.
This Error Applies To
LG DLEX5780VE Series Dryers (2014) (2014–present)
Related Error Codes
Thermistor of blower housing shorted (alternate display for thermistor fault)
Door switch abnormal
Water supply pump failure — pump AD value below 10 in test mode
Steam generator thermistor open or shorted
Power supply wire connection wrong or loose (Black-White-Red wiring)
EEPROM operation abnormal