Error Code tE1
Thermistor of blower housing open or shorted
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE1
How to Fix
- 1
Enter diagnostic test mode: press POWER while pressing MORE TIME and LESS TIME simultaneously.
- 2
If tE1 appears, thermistor is open or shorted.
- 3
Turn power off and discharge voltage (contact metal plug of power cord with ground).
- 4
Remove NA6 connector from controller.
- 5
Short Pin 4 (Blue Wire) and Pin 5 (Orange Wire) together with a metal wire.
- 6
If controller now responds correctly, check that NA6 connector and 6-pin connection to controller are properly connected; replace controller if not.
- 7
If controller does not respond after shorting, remove harness from thermistor assembly connector and measure resistance.
- 8
Compare resistance to Table 1: at 50F/10C expect 18.0kΩ, at 70F/21C expect 11.7kΩ, at 90F/32C expect 7.7kΩ, at 110F/43C expect 5.2kΩ, at 130F/54C expect 2.9kΩ.
- 9
If resistance is out of range, replace thermistor assembly.
- 10
If resistance is in range, check harness-linking connector for continuity.