Error Code dE
Door switch abnormal
Moderate
Address soon - your appliance may not work properly
Also displayed as: dE
How to Fix
- 1
Activate diagnostic test mode: press POWER while pressing MORE TIME and LESS TIME simultaneously.
- 2
dE error only appears in test mode.
- 3
Turn power off and discharge voltage.
- 4
With door closed, measure resistance between BL2-3 (White wire) and BK2-3 connector after removing BL2 and WH4 from controller; expect below 2500Ω.
- 5
With door open, measure resistance between BL2-3 (White wire) and BK2-3 (Black wire); expect 300–600Ω.
- 6
With door open, measure resistance between WH4-2 (Yellow wire) and BL2-3 (White wire); expect below 10Ω.
- 7
With door closed, measure resistance between WH4-2 (Yellow wire) and BL2-3 (White wire); expect below 10Ω.
- 8
Check door switch per component testing procedures (COM-NC terminals).
- 9
Check lamp — if door lamp is faulty it can affect door circuit; replace lamp and re-measure.
- 10
If all switch measurements pass, check controller and harness-linking connectors.
- 11
Replace door switch if COM-NC(1-3) does not read below 12Ω when door knob is open.
This Error Applies To
LG DLEX5780VE Series Dryers (2014) (2014–present)
Related Error Codes
Thermistor of blower housing shorted (alternate display for thermistor fault)
Water supply pump failure — pump AD value below 10 in test mode
Thermistor of blower housing open or shorted
Steam generator thermistor open or shorted
Power supply wire connection wrong or loose (Black-White-Red wiring)
EEPROM operation abnormal