Error Code tE1
Thermistor fault — blower housing thermistor open or shorted
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE1
How to Fix
- 1
Turn power off and discharge capacitors by contacting metal plug of power cord with ground.
- 2
Remove connector NA6 from the controller.
- 3
Short Pin 2 (Blue Wire) and Pin 5 (Orange Wire) on the NA6 connector to the controller.
- 4
If the error clears, check that the control connector and 6-pin harness are properly connected; replace controller if defective.
- 5
If error does not clear, measure resistance between thermistor assembly connector terminals after separating harness.
- 6
Compare measured resistance against Table 1: at 50°F (10°C) expect 18.0kΩ, 70°F (27°C) = 9.3kΩ, 100°F (38°C) = 6.2kΩ, 120°F (49°C) = 4.3kΩ, 140°F (60°C) = 3.0kΩ.
- 7
If resistance is out of range, replace the thermistor assembly.
- 8
If resistance is in range, inspect and repair harness-linking connector.
- 9
tE1 error is displayed during the drying cycle or in test mode.