Error Code tE2
Thermistor fault — blower housing thermistor open or shorted (alternate code)
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE2
How to Fix
- 1
Follow the same diagnostic procedure as tE1.
- 2
Turn power off and discharge capacitors.
- 3
Remove connector NA6 and short Pin 2 (Blue Wire) and Pin 5 (Orange Wire) to the controller.
- 4
If error clears, verify harness connections and replace controller if needed.
- 5
If error persists, measure thermistor resistance and compare to Table 1 values.
- 6
Replace thermistor if out of range; inspect harness connector if in range.