Error Code 9E1
Your dryer is getting the wrong voltage from the outlet
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 9E1
What This Means
Not using regular power source (voltage out of range); Over-voltage condition from utility; Faulty outlet or wiring; Voltage sense circuit fault on PCB
What actually causes this:
The electrical outlet isn't providing the right power — could be a tripped breaker, loose plug, or wiring issue.
First Thing to Check
Check your electrical panel and make sure the dryer's breaker hasn't tripped — flip it fully off then back on.
Parts Involved
How to Fix
- 1
1. Measure voltage at the outlet: should be 240V (electric) or 120V (gas)
- 2
2. Check for blown fuse or tripped circuit breaker
- 3
3. Verify dryer is on a dedicated circuit (30A for electric, 15A for gas)
- 4
4. Check wire harness connections to PCB
- 5
5. Check power supply integrity
- 6
6. If voltage is correct and wiring intact, replace main PCB
Other Error Codes for DV56H9100GG
Your dryer isn't heating properly or is overheating
Your dryer is getting the wrong type of electrical power
Your dryer's temperature sensor isn't reading correctly
The door switch isn't working properly
The dryer's memory chip has a communication error
The dryer's internal parts aren't communicating properly
The dryer thinks the door is open while running
A button on the control panel is stuck or shorted